CO2, GAS DAN FM200 SYSTEM

PINACO range of ‘K85’ High Pressure CO2 Cylinders Hardware is recommended as a low cost and quality product engineered to International standards such as BS 5306, NFPA 12 DIN 17660
Standards.

Products are assembled and tested in accordance to Multron’s certified
ISO 9001 : 2000 Quality Management System.

Carbon dioxide is a by-product of the manufacturing process of other products. This would normally be released into the atmosphere and is the same gas that is used in the medical and carbonation industry. It is also a gas that is naturally produced by nature. Carbon dioxide has been used with proven effectiveness for many years and will continue to be used in the future.

The K85 Valve c/w Cylinder is factory filled with carbon dioxide. A single cylinder may be used, or multiple cylinders can be manifold together to obtain the required quantity of agent for total flooding or local application methods. The K85 valve can be actuated electrically, pneumatically, and / or manually with the appropriate valve actuation components.

 

Cylinder Model Weight of CO2 Cylinder Capacity
K85 – 45 45 kg 68 Litres
K85 – 30 30 kg 45 Litres
K85 – 9 9 kg 13 Litres

Technical Specifications of K85 Valve

Material : Forged Brass CuZn39Pb3
Type of Operation : Manual / Electric /Pneumatic
Leakage Test : 120 Bar
Bursfing Test : 250 Bar
Standard of Compliance : DIN 17660

CO2, GAS DAN FM200 SYSTEM

PINACO C02 fire extinguishing system minimizes the potential loss of life and property in today’s highly specialized environment and can be used safely and effectively. It has a high ratio of expansion, which facilitates rapid discharge and allows for three-dimensional penetration of the entire hazard area quickly.

CO2 extinguishes a fire by reducing the oxygen content of the protected area below the point where it cannot support combustion. Due to the extreme density of the CO2, it quickly and effectively permeates the protected hazard area and suppresses the fire. Rapid expansion of the gas reduces the ambient temperature in the hazard area, which aids in the extinguishing process and retards re-ignition.

When designed, engineered and properly inslied it will not normally damage sensitive electronics equipment. CO2 has no residual to clean up associated with its use as fire suppressing agent. When it is properly ventilated, the gas escape to atmosphere after the fire has been extinguished.

CO2 can be used to protect a wide variety of hazards, from dedicated electronic equipment to high voltage electrical equipment, without any danger or damage.

APPLICATIONS :

  • Battery Rooms
  • Generator Rooms
  • Electrical Area
  • Engine Rooms
  • Flammable Liquid Storage
  • Paint Lockers

PINACO provides the flexibility of selecting & integrating the right Cylinders Hardware & Alarm Davides into Systems to suit Customers needs, in terms of :

> Cost…
> Applications …
> Specifications…

GASEOUS FIRE SUPPRESSION SYSTEMS

FM200 (HFC 227ea) SYSTEMS

APPLICATIONS :

  • Computer Areas
  • Gas Turbines
  • Oil Industry Installations
  • Telecommunications
  • Power Generation
  • Shipping
  • Museums and Archives

Electrically non-conductive, FM-200 (HFC227ea) occupies minimal storage space and has zero effect on the earth’s stratospheric ozone layer. Its primary action is through cooling the fire and removing heat energy so that the combustion reaction cannot be sustained.

Safety is not an issue. In fact, FM-200 has even been used as a replacement for CFC propellants in pharmaceutical inhalers. It is the ideal long term replacement agent and the gas is approved by UL, FM, LPCB and listed in the NFPA 2001.

Furthermore FM-200 contains no particles or residues, therefore it required no clean-up after discharge. It also virtually eliminates the risk of damage to delicate equipment caused by the extinguishant itself.

CO2 SYSTEMS

APPLICATIONS :

  • Battery Rooms
  • Generator Rooms
  • Engine Rooms
  • Flammable Liquid Storage
  • Paint Lockers
  • Spray Booth
CO2 extinguishes a fire by reducing the oxygen content of the protected area below the point where it cannot support combustion. Due to the extreme density of the CO2, it quickly and effectively permeates the protected hazard area and suppresses the fire. Rapid expansion of the gas reduces the ambient temperature in the hazard area, which aids in the extinguishing process and retards re-ignition.

When designed, engineered and properly installed, it will not normally damage sensitive electronics equipment. CO2 has no residual to clean up associated with its use as fire suppressing agent. When it is properly ventilated, the gas escape to atmosphere after the fire has been extinguished.

CO2 can be used to protect a wide variety of hazards, without any danger or damage.

ACCESSORIES

Gas Control Panel

Gas Control Panel

Manual Release and Abort Station

Flashing Sign

Warning Signage

FIGURE 1

A TOTAL FLOODING SYSTEM CONSISTS OF A FIXED SUPPLY OF CARBON DIOXIDE CONNECTED TO FIXED PIPING WITH NOZZLES ARRANGED TO DISCHARGE CARBON DIOXIDE INTO AN ENCLOSED SPACE AROUND THE HAZARD

FIGURE 2

A LOCAL APPLICATION SYSTEM CONSISTS OF A FIXED SUPPLY OF CARBON DIOXIDE CONNECTED TO FIXED PIPING WITH NOZZLES ARRANGED TO DISCHARGE CARBON DIOXIDE DIRECTLY ONTO THE PROTECTED HAZARD.

FIGURE 3

A HAND HOSE LINE CONSISTS OF A FIXED SUPPLY OF CARBON DIOXIDE SUPPLYING HOSE LINES.

A CO2 installation consists of one or more cylinders of’ carbon dioxide connected through a manifold to a distribution pipework. The distribution pipework ends in special carbon dioxide discharge nozzles.

The quantity of carbon dioxide required for installation and the strategic placement of the discharge nozzles is determined by our experience staff. Our designer will study the location, the cubic capacity or surface area of the hazard and the type of material involved.

More than one hazard can be protected by the same bank of cylinders. Selector or directional valves areMused to direct the carbon dioxide to the fire area.

An interconnected reserve bank of cylinders is desirable for some
applications for added protection.

The System can be manually or automatically activated in conjunction with a Fire Detection & Alarm System.

Referensi Video CO2 Gas dan FM200 System